Show simple item record

dc.contributor.authorGonzález-Suárez A.
dc.contributor.authorBerjano E.
dc.date.accessioned2016-06-13T13:44:26Z
dc.date.available2016-06-13T13:44:26Z
dc.date.issued2016-01-01
dc.identifier.issn0018-9294
dc.identifier.urihttp://hdl.handle.net/20.500.11824/271
dc.description.abstractOur aim was to compare the different methods of modeling the effect of circulating blood flow on the thermal lesion dimensions created by radio frequency (RF) cardiac ablation and on the maximum blood temperature. Computational models were built to study the temperature distributions and lesion dimensions created by a nonirrigated electrode by two RF energy delivery protocols (constant voltage and constant temperature) under high and low blood flow conditions. Four methods of modeling the effect of circulating blood flowon lesion dimensions and temperature distribution were compared. Three of them considered convective coefficients at the electrode-blood and tissue-blood interfaces to model blood flow: 1) without including blood as a part of the domain; 2) constant electrical conductivity of blood; and 3) temperaturedependent electrical conductivity of blood (+2%/°C). Method 4) included blood motion andwas considered to be a reference method for comparison purposes. Only Method 4 provided a realistic blood temperature distribution.The other three methods predicted lesion depth values similar to those of the reference method (differences smaller than 1 mm), regardless of ablation mode and blood flow conditions. Considering the aspects of lesion size and maximum temperature reached in blood and tissue, Method 2 seems to be the most suitable alternative to Method 4 in order to reduce the computational complexity. Our findings could have an important implication in future studies of RF cardiac ablation, in particular, in choosing the most suitable method to model the thermal effect of circulating blood.
dc.formatapplication/pdf
dc.languageeng
dc.publisherIEEE Transactions on Biomedical Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/es/
dc.subjectBlood flow
dc.subjectCardiac ablation
dc.subjectCatheter ablation
dc.subjectComputer modeling
dc.subjectRadio frequency (RF) ablation
dc.subjectThermal modeling
dc.titleComparative analysis of different methods of modeling the thermal effect of circulating blood flow during RF cardiac ablation
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/acceptedVersion
dc.identifier.doi10.1109/TBME.2015.2451178
dc.relation.publisherversionhttp://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7174551


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

info:eu-repo/semantics/openAccess
Except where otherwise noted, this item's license is described as info:eu-repo/semantics/openAccess